Standard
WULI Standard Misting System Overview
Fully Integrated Standard High-Pressure Misting Systems: Turnkey & High-Reliability Climate Control Solutions
WULI standard high-pressure misting systems are engineered as modular, fully integrated fogging units. By housing the high-pressure pump, driving motor, and electronic control modules within a single heavy-duty enclosure, we eliminate complex field assembly. On-site contractors only need to connect the inlet/outlet water lines and nozzles to achieve immediate, industrial-grade atomization. Designed specifically for engineering efficiency, structural rigidity, and continuous long-term operations in rigorous industrial and commercial environments.
【Precision Selection】Configure Your Optimal Misting System by Power Frequency and Flow Demand
Our standard high-pressure misting system line encompasses a full range of flow capacities, meticulously optimized with dedicated motors and pumps according to regional power frequencies (50Hz / 60Hz). Procurement managers and system engineers can rapidly identify the correct model based on total coverage area, total nozzle counts, and localized grid specifications to significantly compress project installation times:
■ 50Hz Power Grid Applications: The -5M Series
Recommended Models: WM-1001B-5M (Low Flow) / WN-1003A-5M (Medium Flow) / WN-1004A-5M (Medium-High Flow)
Target Markets & Venues: Europe, Middle East, and Southeast Asia operating on 50Hz power grids. Delivers consistent volumetric flow output tailored to large-scale infrastructure and agricultural projects.
■ 60Hz Power Grid Applications: The -6M Series
Recommended Models: WM-1001B-6M (Low Flow with 110V/220V Dual Availability) / WN-1003A-6M (Medium Flow, 220V Exclusive) / WN-1005A-6M (High Flow, 220V Exclusive)
Target Markets & Venues: North America, Taiwan, and the Philippines operating on 60Hz power grids. Engineered specifically to withstand severe load profiles in massive industrial factories and high-capacity dust mitigation zones.
What is a High-Pressure Misting System? Core Metrics for B2B Procurement
Modern high-pressure misting systems utilize industrial-grade positive displacement pumps to accurately pressurize water, forcing it through specialized precision-orifice nozzles to atomize the stream into micron-level droplets. As these ultra-fine mist particles rapidly flash-evaporate in the air, they absorb massive amounts of ambient thermal energy, resulting in significant and immediate temperature reduction over vast areas while balancing relative humidity and precipitating airborne particulate matter.
As an OEM/ODM manufacturer, WULI Pump’s standardized enclosed design seals the traditionally loose components—peripheral plumbing, electronics, and motor basements—into a unified, heavy-duty housing. This structural approach completely mitigates vibration wear, electrical overloads, and environmental corrosion common in punishing industrial processes.
WM Series | Compact High-Pressure Misting Systems (WM-1001B-5M / WM-1001B-6M)
Engineered for Precision Humidification and Light-Duty Climate Control
The WM-1001B series represents a space-saving, turnkey misting solution that expertly balances a high-efficiency pump with a smart control timer. It is purpose-built for refined zones, including localized plant factory humidification, commercial outdoor hospitality cooling, and upscale residential setups, delivering superior atomization quality alongside quiet, energy-saving performance. Depending on regional grid requirements, it is available as the 50Hz WM-1001B-5M or the 60Hz WM-1001B-6M (with the 60Hz model featuring versatile 110V or 220V wiring configurations).
Key Product Features
- Fully Enclosed Structural Integrity: Built-in premium pump and comprehensive control modules optimize footprint and simplify maintenance routines.
- Zero-Barrier Installation: Standardized inlet/outlet plumbing ports enable instantaneous setup—simply lay down the tubing, mount nozzles, connect power, and operate.
- Low Capex & High Efficiency: Minimal power consumption combined with sustained, micro-fine droplet distribution.
Dual Smart Timer Options (Customized per Process Specifications)
To accommodate diverse environmental control logics, this series offers two factory-configured control panels:
- Mechanical Dual-Setting Timer: Utilizing a rugged dual-knob layout, operators can freely and independently adjust "Mist Duration" and "Interval Delay" (e.g., 15 seconds on, 45 seconds off). Ideal for variable commercial environments requiring rapid, on-the-fly tactical adjustments.
- Electronic Three-Stage Timer: Governed by a digital chip, this option features a "Continuous Mist" mode alongside three pre-programmed operational cycles. The interface is intuitive, making it the premier choice for standard operating procedures (SOP) in commercial franchises or automated industrial lines.
WN Series | Medium to High-Flow High-Pressure Misting Systems
Built for Global Power Infrastructures and Continuous Heavy-Duty Demands
The WN standard misting series is WULI Pump’s core workhorse line developed for expansive areas, high volumetric water demands, and prolonged duty cycles in industrial and agricultural engineering. To guarantee maximum motor efficiency and extract the full rated flow rate from the high-pressure pump, this series strictly isolates internal circuitry by power frequency, eliminating motor overheating or pressure drops caused by mismatched grid setups on site.
50Hz Dedicated Models (Suffix -5M; Engineered for Europe, Middle East, Southeast Asia)
- WN-1003A-5M: 50Hz dedicated medium-flow system (Rated Voltage: 230V). Supplies a highly stabilized mist output perfectly suited for commercial open-air venues and commercial greenhouse complexes.
- WN-1004A-5M: 50Hz dedicated medium-high flow system (Rated Voltage: 230V). Unleashes higher volumetric output capacity, optimized for international smart agriculture and large facility climate matrices.
60Hz Dedicated Models (Suffix -6M; Engineered for North America, Taiwan, Philippines)
- WN-1003A-6M: 60Hz dedicated medium-flow system (Rated Voltage: 220V). Formulated for commercial and industrial power grids, providing flexible adaptability across various manufacturing layouts.
- WN-1005A-6M: 60Hz dedicated heavy-duty high-flow system (Rated Voltage: 220V). Delivers maximum volumetric displacement to easily manage extensive, high-density nozzle networks in massive factory cooling and harsh industrial dust suppression setups.
International Utility Match for Global Export and Cross-Border Projects
To satisfy the strict requirements of international procurement managers and global engineering contractors, WULI standard high-pressure misting systems provide a complete grid-matching matrix, allowing seamless integration into local utilities without requiring auxiliary transformers:
- • 50Hz Regions (Single-Phase 230V): Fully compatible with WM-1001B-5M / WN-1003A-5M / WN-1004A-5M
- • 60Hz Regions (Single-Phase 110V / 220V): Compact WM-1001B-6M supports 110V or 220V; heavy-duty WN-1003A-6M and WN-1005A-6M systems require dedicated 220V commercial-grade supply.
Primary Target Industries and Proven Applications
Thanks to their high level of integration and exceptional mechanical endurance, our standard systems are actively deployed across vital global sectors:
- Industrial Factory Cooling: Temperature reduction across wide-span steel mills, foundries, textile facilities, and electronics assembly lines to boost labor productivity.
- Greenhouse Humidification & Agriculture: Precise micro-climate management for commercial mushroom cultivation, orchid nurseries, and vertical indoor farms.
- Dust Suppression Systems: Tactical airborne dust capture and particulate precipitation in quarry yards, cement plants, demolition sites, and recycling facilities to comply with environmental regulations.
- Outdoor Commercial Hospitality: Ambient cooling for amusement parks, public landmarks, open-air shopping centers, and restaurant patios.
- Logistics & Warehousing Control: Micro-climate stabilization in wide-area logistics terminals and cold-chain staging zones to protect temperature-sensitive goods.
Standard High-Pressure Misting System Specifications
| Model Number | System Classification | Grid Frequency | Compatible Rated Voltage | Control Panel Configuration |
|---|---|---|---|---|
| WM-1001B-5M | Low Flow / 50Hz Compact Enclosed | 50Hz | 230V Single-Phase | Mechanical Dual-Setting / Electronic 3-Stage Timer |
| WN-1003A-5M | Medium Flow / 50Hz Global Standard | 50Hz | 230V Single-Phase | Industrial Integrated Control Array |
| WN-1004A-5M | Medium-High Flow / 50Hz Heavy-Duty | 50Hz | 230V Single-Phase | Specialized Heavy-Duty Export Control Array |
| WM-1001B-6M | Low Flow / 60Hz Compact Enclosed | 60Hz | 110V / 220V Single-Phase | Mechanical Dual-Setting / Electronic 3-Stage Timer |
| WN-1003A-6M | Medium Flow / 60Hz Commercial Grade | 60Hz | 220V Single-Phase | Industrial Integrated Control Array |
| WN-1005A-6M | High Flow / 60Hz Max Capacity | 60Hz | 220V Single-Phase | Heavy-Duty Motor Drive & Central Control Array |
Standard High-Pressure Misting Systems FAQ
Q1. Is this a fully integrated system or simply a bare high-pressure pump?
This product is a completely turnkey, fully integrated high-pressure misting system. The heavy-duty housing securely contains the high-pressure pump, direct-coupled motor, thermal overload protectors, and electronic timer modules. Upon delivery, there is no need for complex electrical wiring or motor shaft realignment. Field engineers only need to hook up a water source, route the high-pressure tubing line with nozzles, and plug into the correct power supply to commence operations.
Q2. What do the -5M and -6M model suffixes indicate, and how should we select them?
The suffixes directly define the target electrical grid frequency of the equipment: -5M signifies 50Hz, while -6M signifies 60Hz. This designation is crucial for international projects. For instance, if your facility is located in Europe, the Middle East, or Southeast Asia (50Hz regions), you should specify the WM-1001B-5M, WN-1003A-5M, or WN-1004A-5M. For sites in North America or Taiwan (60Hz regions), select the -6M line. Matching the correct frequency ensures the motor operates in its peak efficiency zone and prevents premature equipment wear.
Q3. Do all models in the 60Hz product line support standard 110V utility outlets?
No, they do not. Within our 60Hz product lineup, only the compact WM-1001B-6M supports 110V and 220V configurations. The mid-to-high flow industrial units, namely the WN-1003A-6M and WN-1005A-6M, are exclusively built for 220V single-phase power. Because high-flow systems demand immense mechanical driving torque, a dedicated 220V line ensures optimal voltage stability and mitigates any voltage sag or breaker trips under continuous operation.
Q4. What distinct advantages do these enclosed systems offer for harsh dust suppression or high-humidity greenhouses?
Traditional open-frame or custom-assembled misting rigs frequently suffer from premature electrical failure or motor damage caused by heavy particulate ingestion or extreme relative humidity. WULI standard systems feature a fully enclosed protective housing that seals all critical mechanical and electrical components away from ambient hazards. This significantly boosts resistance to fine dust and moisture, ensuring thousands of hours of reliable, continuous service under the most unforgiving industrial and agricultural operations.


